079 65246510 / 20

Ahmedabad, Gujarat (India)

triangle
About Us

Braided Cables

Data transmission cables

Applications : Is suitable for interconnection of electrical measuring devices to Instrument panel or instrument. Measuring, monitoring and control in machine tool manufacturing, in plant engineering, in all places where electrical interference fields can distort a signal transmission or where Interference pulses arising in the mains must be confined.

Technical Data : Special PVC data cables, adapted to DIN VDE 0245 The material used in manufacture is cadmium free and contains no silicone and free of substances harmful to the wetting properties of Lacquers.

Coupling Resistance : < 250 ohm

Temperature Range : Flexing -5 C to +80 C

Nominal Voltage : Uo / 500 V

Test Voltage : 3000 V.

Insulation Resistance : Min. 20 Mohm x km

Mutual Capacitance : According to different cross sections Core / Core approx, 150 nF / km. Core / Screen approx, 270 nF / km

Minimum Bending Radius : Approx. 10 x cable

Cable Structure : Bare copper, fine wire conductors, bunch 0 0 Fixed Installation -20 C to +80 C stranded to IS 8130 class 5 and IEC 60228 class 5. Core insulation of special PVC Type A IS 5831, TI 1 DIN VDE 0207 Part 4. Coloured cores upto 4 cores only. Continuous numbering in white and one green / yellow core from 5 core onwards. Cores stranded in layers with optimal lay-length. Core Wrapping withcopper mylartape. Tinned copper braided screen, Approx. 85% coverage. Special PVC outer sheath TYPE ST1 of IS 5831, TM2 DIN VDE 0281 Part 1 and HD 21.1, sheath colour grey. Extensively Oil Resistant, Chemical Resistant. PVC self- extinguishing and flame retardant, test according to IS 694, DINVDE 0472 Part 804 and IEC 60332-1

No.of cores
per conductor

no. of sq mm²
per conductor

Approx cable
diameter in mm

Copper
Weight
Kg/km

Approx
Weight
Kg/km

2
3
4
5
6
7
8
10
12
14
16
18

0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

5.3
5.6
6.2
6.7
7.4
7.9
8.5
9.3
9.6
10.0
10.7
11.2

21
25
35
33
39
43
49
60
67
78
88
96

57
64
84
89
107
121
138
167
180
201
228
249

2
3
4
5
6
7
8
10
12
14
16
18

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75

5.7
6.2
6.7
7.2
8.0
8.6
9.4
10.2
10.4
11.1
11.6
12.4

25
31
38
45
53
59
68
83
93
106
121
134

66
79
93
109
132
150
177
211
224
255
284
319

No.of cores
per conductor

no. of sq mm²
per conductor

Approx cable
diameter in mm

Copper
Weight
Kg/km

Approx
Weight
Kg/km

2
3
4
5
6
7
8
10
12
14
16
18

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

6
6.5
7.1
7.6
8.5
9.1
9.9
10.8
11.2
11.8
12.3
13.2

29
37
46
56
66
74
84
104
119
137
154
172

74
90
108
127
154
175
203
246
270
305
335
380

2
3
4
5
7
8

1.5
1.5
1.5
1.5
1.5
1.5

8.5
7.6
8.2
9.1
10.8
11.6

37
50
62
76
100
115

128
121
145
177
242
279

2
3
4
5
7
12

2.5
2.5
2.5
2.5
2.5
2.5

8.6
9.4
10.2
11.3
13.5
16.7

55
76
96
117
157
261

146
183
221
270
375
591

* The above data is indicative and may be revised without prior intimation. The above dimensions are not applicable for UL 1007 & 1569. Conductor as per IS 8130: 84, Class 5